A masonry fireplace needs its own reinforced concrete footing. The footing must be at least 12 in thick and extend at least 6 in past the fireplace on every side. It must sit below local frost depth, on undisturbed soil or properly engineered fill. A factory-built unit needs no masonry footing. It sits on a framed floor and follows its listing.
The masonry footing
- Size. At least 12 in thick, and extending at least 6 in past the fireplace on every side.
- Depth. Below local frost depth. Frost depth varies by region, and your building department sets the local number.
- Soil. Undisturbed soil or properly engineered fill. Soft, uneven, or disturbed ground needs more work before the footing goes in.
- Concrete. The residential code sets a minimum concrete strength, which runs from about 2,500 to 3,500 psi depending on how much weathering the concrete will face.
- Reinforcement. Footings are commonly reinforced with steel bars. In some seismic design categories, the code requires vertical chimney reinforcement to anchor into the footing.
A masonry fireplace and chimney can weigh several tons. The footing spreads that load over the ground and helps keep the structure from settling. A chimney that is poorly supported can lean or crack.
Upper floors cannot carry it
A masonry fireplace on an upper floor still needs its footing at ground level. Floor framing is not designed to carry the weight of masonry. The load has to reach the ground through the structure, which is why the footing belongs at the bottom of the building.
Hearth and hearth extension
The hearth is the floor surface in front of the fireplace opening. Two parts matter for safety:
- Masonry hearth. At least 4 in thick, and supported by noncombustible construction.
- Hearth extension. At least 2 in thick and noncombustible. It must be at least 16 in in front and 8 in on each side for openings under 6 sq ft. For openings of 6 sq ft or more, it must be at least 20 in in front and 12 in on each side. Some raised-firebox designs allow a thinner extension, so check the code for your case.
If you build the hearth over wood forms or centering, remove the combustible forms after construction. The code requires it.
The hearth extension is fire protection, not decoration. It keeps sparks and embers off the floor. To work out the opening area, see standard fireplace dimensions.
Prefab, wood stove and masonry heater bases
- Prefab (UL 127) fireplaces. No masonry footing is needed. The unit sits on a framed floor, and the hearth extension follows the listing.
- Wood stoves. Need a hearth pad that meets the stove’s listing and the clearances in the manual. Use the thickness or R-value the manual specifies.
- Masonry heaters. Weigh a few thousand pounds or more, and usually need their own footing.
Signs of foundation trouble
- A chimney that leans, bulges, or pulls away from the house
- Cracks in the masonry, especially in a stair-step pattern along the mortar joints
- A firebox or hearth that has shifted or separated from the wall
- Doors or smoke behaving differently after the ground has settled
A leaning chimney is not just a cosmetic problem. It often means the footing has failed or the ground has settled. If you see these signs, have a licensed mason or structural engineer look at it, and do not use the fireplace until the chimney has been assessed.
When to call an engineer
Get an engineer involved for:
- Expansive or unstable soils
- Sloped ground or fill
- Adding a fireplace to an existing slab. An ordinary slab-on-grade is usually not designed for masonry fireplace loads, unless it was designed for them.
- Any project where the loads or the ground are unclear
For what happens during construction, see how fireplaces are constructed. For the broader overview, see wood burning fireplace construction.