Building a Fireplace

How are fireplaces constructed?

Masonry fireplaces are built up from a footing through the firebox, damper, smoke chamber and flue. Here is the build order, plus how prefab units go in.

On this page
  1. Two construction methods
  2. Build order for a masonry fireplace
  3. How a factory-built fireplace goes in
  4. Minimums to keep in mind during construction
  5. Finishing the hearth, surround and mantel
  6. Where to go next

A masonry fireplace is built up from a footing. It has a firebox lined with firebrick, a damper, a smoke chamber that funnels smoke into a flue, and a chimney finished with a crown and cap. A factory-built fireplace is a listed metal firebox set into a framed opening and connected to a listed chimney. Both must meet the clearances and minimums in the building code and in the appliance listing.

Two construction methods

Masonry fireplaces are built on site from brick, stone, or block, with a firebox of firebrick. They are heavy, permanent, and built one course at a time by a mason.

Factory-built fireplaces are manufactured and tested as a unit. They are installed into a framed opening and vented through a chimney system listed for that unit. Because the listing controls what can be used, the parts and clearances must match the maker’s instructions.

Build order for a masonry fireplace

  1. Footing. Pour a reinforced concrete footing at least 12 in thick. It should extend at least 6 in past the fireplace on each side, and sit below frost depth.
  2. Hearth and ash pit base. Build the base and the hearth on the footing. The hearth is the noncombustible surface in front of the opening, and it is usually at least 4 in thick.
  3. Firebox. Build the firebox walls from firebrick laid in refractory mortar. Total wall thickness is at least 8 in, including at least 2 in of firebrick lining, or 10 in of solid masonry if the walls are unlined. The firebox should be at least 20 in deep. Rumford-style fireboxes, which are shallower and angled, follow different minimums.
  4. Throat and damper. Above the opening, form the throat, which must sit at least 8 in above the top of the opening. Install the metal damper in or just above the throat. Codes require a damper.
  5. Smoke chamber. Build the smoke chamber above the damper. It narrows upward to funnel smoke into the flue. Codes limit how steeply the chamber walls can slope, and masons follow the code tables for the wall type they use.
  6. Flue and chimney. Install the flue liner, either clay or a listed metal liner, and build the chimney around it. Keep an airspace between the liner and the masonry. The chimney walls are at least 4 in of solid masonry around the liner.
  7. Crown and cap. Finish the top with a sloped concrete or mortar crown that has an overhang and a drip edge. Add a spark arrestor cap.

Chimney height is set by the rule that the top must be 3 ft above the roof penetration and 2 ft above anything within 10 ft horizontally. The 2 + 10 rule article explains how to measure it.

How a factory-built fireplace goes in

  • Frame the floor and opening. A factory-built unit sits on a framed floor and needs no masonry footing. The framing has to carry the unit’s weight, which is usually a few hundred pounds.
  • Set the firebox. Place the unit in the framed opening and anchor it as the manual describes.
  • Install the listed chimney system. Use the maker’s chimney parts. Mixing brands can void the listing.
  • Keep the clearances. Hold the distances the manual gives from combustible framing and drywall.
  • Finish the face. Add a noncombustible surround, the hearth extension required by the listing, and any mantel. For a gas unit, a licensed technician connects and tests the gas line.

Minimums to keep in mind during construction

  • Hearth extension: at least 16 in in front and 8 in on each side for openings under 6 sq ft. For openings of 6 sq ft or more, it is 20 in in front and 12 in on each side. The standard fireplace dimensions guide shows how to work out the opening area.
  • Clearance to combustible framing: at least 2 in at the front and sides, and 4 in at the back.
  • Forms: remove any combustible forms used to build the hearth once the work is done.
  • Liner airspace: do not fill the gap between the flue liner and the masonry with mortar.

Finishing the hearth, surround and mantel

The hearth extension is fire protection, not decoration. It keeps sparks and embers off the floor. The surround and mantel come last, but they are still part of the safety design. Combustible material must stay back from the opening, and a mantel or trim near the opening can project only a limited amount. The foundation and hearth guide covers the hearth base in more detail.