The 2 + 10 rule is the part of the 3-2-10 chimney rule that sets how high the chimney top must be relative to nearby structures. The chimney must rise at least 2 ft above any part of the roof or building within 10 ft horizontally. The full 3-2-10 rule adds a requirement at the roof: the chimney must also extend at least 3 ft above the point where it exits the roof.
The rule in plain terms
The rule has two parts:
- The chimney top must be at least 3 ft above the highest point where the chimney passes through the roof.
- The chimney top must be at least 2 ft higher than any part of the roof or any nearby structure within 10 ft horizontally.
Together these make up the 3-2-10 rule. The “2 + 10” phrase refers to the second part.
How to measure it
- Measure horizontally. Measure 10 ft straight out from the chimney, not along the roof slope and not straight up.
- Check everything in that circle. This includes roof planes, ridges, dormers, and the walls of any other structure within 10 ft.
- Watch for a nearby ridge. If the ridge is within 10 ft, the chimney must be at least 2 ft above the ridge.
- Measure to the top of the flue. Caps are generally not counted. Check the listing for the specific product.
- Expect taller chimneys on steep roofs. On a steep roof, meeting the rule can take several extra feet of chimney above the roof.
Where it applies
The rule applies to solid-fuel fireplaces and their chimneys, including masonry fireplaces and factory-built chimneys listed for solid-fuel use.
It does not apply to direct-vent gas appliances, which have their own termination clearances. Gas appliance vents follow the appliance manual and the code’s venting tables. Do not apply the 2 + 10 rule to a gas vent by default.
Why the rule exists
A chimney has to pull smoke up and out. If the chimney top sits in the wind pressure zone created by the roof or a nearby building, wind can push down the flue instead. That can cause:
- Downdrafts that push smoke back into the living space
- Hot embers landing near the roof surface
- Carbon monoxide entering the home if the venting does not work as intended
Meeting the rule does not guarantee good draft. Nearby trees, taller buildings, and the pressure inside the house still affect how a chimney performs.
Common misunderstandings
- “It is 2 ft above the roof.” Not quite. It is 2 ft above anything within 10 ft, plus 3 ft above the point where the chimney exits the roof.
- “Ten feet is measured along the roof slope.” It is measured horizontally.
- “The cap counts toward the height.” Generally it does not.
- “If my chimney passes the rule, my draft is fine.” Not necessarily. The rule is about the position of the top, not a guarantee of how well the fireplace draws.
- “The rule applies to my gas fireplace.” Gas venting has its own rules.
If your chimney falls short
- Extend the chimney. A masonry extension or a listed metal extension can raise the top. Tall metal extensions above the roof often need manufacturer bracing, so check the requirements for the brand you use.
- Add a listed cap or a draft device. This may help, depending on the cause of the problem.
- Have it assessed. A certified chimney sweep or inspector can check the flue, the draft, and the damper before you decide on a fix.
- Stop using the fireplace if smoke spills into the room. Get it checked before you burn again.
Related reading
The rule also applies to fireplaces in manufactured homes, where the chimney must be the listed system the appliance maker specifies. For how the chimney fits into the full build, see how fireplaces are constructed.