When a gas fireplace won’t light, the first question is whether the pilot is lit. If the pilot is out, the problem is usually the gas supply, the pilot’s gas flow, or the thermocouple that holds the valve open. If the pilot is lit but the burner won’t come on, the problem is more likely the switch, the remote, or the valve. Check the manual shutoff and the gas supply first, then work through the steps below.
Start With the Gas Supply and Manual Shutoff
- Manual shutoff valve. This is a quarter-turn valve. It’s open when the handle is parallel to the pipe.
- Other gas appliances. If the furnace, water heater or stove also won’t run, the gas supply may be the problem.
- Propane tank. Check the level. A low tank can’t supply enough gas.
- Utility shutoff. The gas utility may have shut off service to the home.
Pilot Out: Lighting and Holding the Pilot
On a standing-pilot unit, turn the knob to PILOT, press it in, and light the pilot. Keep holding the knob for 30 to 60 seconds after the pilot lights. This gives the thermocouple time to heat up. If you let go too soon, the pilot will go out.
After a propane refill or a long shutdown, air can be trapped in the gas line. You may need to hold the knob for a minute or two to purge it.
If the pilot lights but goes out as soon as you release the knob, the thermocouple is the likely cause. It may be weak, misaligned or loose. The thermocouple should give a small voltage, often in the 25 to 30 millivolt range when it’s open-circuit, and a reading below about 20 millivolts is generally weak. Exact values depend on the valve, so check your manufacturer’s specs.
The pilot flame should be steady and blue. It should wrap around the top 3/8 to 1/2 inch of the thermocouple or thermopile. A weak, yellow or lifting pilot usually means a dirty orifice or a spider web. Clean it with compressed air.
Pilot Lit but the Burner Won’t Come On
If the pilot is steady but the main burner won’t light:
- Check the wall switch or remote. A dusty, loose or broken switch can stop the signal from reaching the valve. Dead batteries in the remote can do the same. The remote receiver’s own switch also needs to be set correctly.
- Check for a stuck valve. If you hear a click but no gas reaches the burner, a technician can test whether the valve or the switch is at fault.
- Don’t keep trying. Repeated attempts without gas clearing can be unsafe.
Millivolt wall switches carry under 1 volt, not 120 volts. Still, don’t open the valve compartment or disconnect valve wires unless the manual tells you to. A technician can test the switch and the valve safely.
Cold Starts and Lockout
On cold or damp days, electronic and standing-pilot units can need several tries to light. Cold, heavy air in the vent can smother the pilot before it heats up enough to establish draft. This is a known effect, not a defect.
Too many failed attempts can put an electronic ignition system into lockout. This is a safety feature. To reset it, turn the unit off, wait two or three seconds, and turn it back on. Some models use a reset switch on the control module instead. Check the manual for your model.
Many manufacturers suggest keeping the pilot lit in continuous pilot (CPI) mode during cold or damp weather. The continuous pilot keeps the flue warm and helps the draft form, which can reduce repeated lighting attempts and lockouts. Check your model’s manual for how to switch modes.
Electronic (IPI) Ignition
Electronic intermittent pilot ignition (IPI) uses a spark to light the pilot when you turn the unit on. It needs 120-volt power or battery backup. Some common problems:
- Weak clicking. Replace the batteries in the receiver or battery pack first.
- Lockout after about three failed tries. Reset by cutting power for one to two minutes, or by removing the batteries.
- Clicking, but no light. Check the battery and wiring first. A dirty flame sensor or a poor ground can also cause this.
- Constant sparking after the pilot lights. The flame sensor may be dirty. Clean it gently, or have it checked.
Standing Pilot or IPI: How to Tell
- Standing pilot. A small flame stays lit all the time, and you light it by hand or with a piezo push-button. The pilot is always burning, even when the fireplace is off.
- IPI. There is no pilot flame when the fireplace is off. The unit sparks when you turn it on. It’s usually more efficient, but it needs power or batteries to work.
Knowing which system you have helps you choose the right checks. The fireplace manual will say which one it uses.
When to Call a Technician
Stop troubleshooting and call a certified technician or your gas company if:
- You smell gas. Leave the home, don’t operate switches, and call from outside.
- You hear repeated clicking with no ignition, and basic cleaning and battery changes don’t help.
- The flame is weak, yellow or unusual, or the gas line looks damaged.
Wait at least five minutes between repeated failed attempts so any gas can clear. Gas valve, regulator and pressure work should be done only by a qualified technician.
If the igniter or starter is the problem, see why a gas fireplace starter isn’t igniting. If the fireplace stays on after you switch it off, read why a gas fireplace stays on. For remote issues, see the remote and receiver guide. The cost guide for igniter replacement gives typical part and labor prices.