Common causes of a starter that won’t light include dead or weak batteries, a broken or loose wire on a piezo igniter, a spark gap that has moved, gas not reaching the pilot, or a dirty pilot orifice. A click with no flame usually points to gas flow or the thermocouple, not the igniter itself.
Check the Basics: Gas Supply and Batteries
Start with the simple checks before you touch the igniter:
- Gas supply. Make sure the manual shutoff valve is open. The handle should run parallel to the pipe. On propane, check that the tank isn’t empty.
- Batteries. Electronic igniters often have batteries in more than one place: the igniter button, the receiver or battery pack, and the remote. Check each one. Use fresh alkaline batteries. Rechargeable cells at 1.2 volts can be too weak.
- Control knob. On a standing-pilot unit, the knob has to be in the PILOT position and held down while you try to light it.
Piezo Igniters: No Click, No Spark or a Weak Spark
A piezo igniter is the push-button that creates a spark. The three symptoms point to different problems:
- No click at all. The button or its internal mechanism has likely failed.
- Click but no spark. Look for a loose or broken wire, a cracked ceramic insulator, or an electrode gap that is out of position.
- Weak spark. Check the gap between the electrode and the pilot hood. A gap of about 1/8 inch (roughly 3 mm) is typical, but the exact spacing depends on the model. Check the manual.
To see the spark, darken the room and press the igniter. It should jump from the electrode to the pilot hood. If it doesn’t, the igniter or its wiring is the likely cause.
Electronic Igniters and Batteries
Electronic ignition works from batteries, a 120-volt connection, or a battery backup. Some common symptoms:
- Slow or weak clicking. Replace the batteries with fresh alkaline cells before anything else.
- Lockout after several failed tries. Many intermittent pilot ignition (IPI) systems lock out after roughly three failed attempts. To reset, remove power or batteries for one to two minutes, then restore them.
- Sparking after the pilot lights. This can point to a dirty flame sensor. Clean it gently with fine emery cloth. Don’t use anything coarse.
- Sparks stop after cleaning. Moisture can block sparks until the electrode dries.
Spark but No Flame
If you can see the spark but the pilot doesn’t light, gas isn’t reaching the pilot. Check the shutoff valve, the propane level, and whether the knob is in PILOT and fully pressed. After a tank refill or a summer shutdown, air can be trapped in the line. Hold the knob down and keep sparking to purge it. This can take a minute or two.
A clogged pilot orifice from dust or a spider web also stops the flame. Clear it with compressed air. Don’t use a pin, and don’t enlarge the opening, since that changes how the pilot burns.
When the Pilot Lights and Then Goes Out
If the pilot lights but goes out as soon as you release the knob, the problem is usually the thermocouple, not the igniter. The thermocouple is the safety sensor next to the pilot. It needs to heat up before it holds the gas valve open. Hold the knob down for the time the manual specifies, which is often 30 to 60 seconds. A weak, misaligned or loose thermocouple will keep dropping the pilot.
Replacing the igniter won’t fix this. A new igniter can’t keep the pilot lit.
When to Call a Technician
Stop troubleshooting and call a qualified technician if:
- You smell gas. Leave the home, don’t operate switches, and call the gas utility or 911 from outside.
- You hear repeated clicking with no ignition, and cleaning and battery changes don’t help.
- The pilot flame is weak, yellow or unsteady, or the gas line looks damaged.
Replacing an igniter or thermocouple involves gas connections. Our cost guide for igniter replacement explains what a repair typically runs. If the burner won’t light after the pilot is steady, see our guide to the main burner not igniting. If the remote is the problem, check the remote and receiver batteries.