Fireplace Makeovers

DIY Fireplace Surround Plans: Wood, Wall Panels and Gas Surrounds

DIY fireplace surround plans for wood and MDF surrounds, wall panels and gas units, with clearance rules, materials and finishing tips for each one.

On this page
  1. Know what you’re surrounding
  2. Dimensions and materials
  3. Build the frame and mantel
  4. Finish the surround
  5. Wall panels: noncombustible vs. combustible
  6. Gas and electric surrounds
  7. Common mistakes

A DIY surround can change a plain firebox a lot, and it doesn’t have to be expensive. One blogger built a painted faux-stone surround for about $200 in materials. The clearance rules decide the design, though. A wood surround around a masonry fireplace is different from one around a gas or electric unit, so start with the fireplace type.

Know what you’re surrounding

  • Masonry fireplace: Keep wood and MDF at least 6 inches from the opening. Within 12 inches, the projection can be no more than 1/8 inch for every inch of distance.
  • Prefab or gas unit: Use the manufacturer’s mantel and leg clearance chart. Many units require a noncombustible facing zone around the opening.
  • Direct-vent gas: These units are sealed, and their facing rules are specific to the model.
  • Heat-release gas units: Some have a “cool wall” system that allows combustible finishes or a TV closer, but only as listed.
  • Electric unit: No venting is needed, and most run on a 120-volt plug at about 1,500 watts. This is the simplest DIY surround.

Dimensions and materials

A typical mantel shelf sits about 54 to 60 inches above the floor, though that depends on the opening and the ceiling height. Shelf depth is often 6 to 12 inches, and leg (pilaster) width is often 6 to 12 inches.

Common materials include 2x2 or 2x4 framing, 3/4-inch MDF or poplar, crown and base moulding, construction adhesive and 18-gauge brads. One build guide uses 3/4-inch MDF for the surround, pine face trim and a walnut mantel assembled with pocket holes.

Fill the gap between the opening and the wood with a noncombustible material, such as tile, stone or metal, or tile on cement board.

Build the frame and mantel

Fix the frame to masonry with masonry screws, such as Tapcons, and fix it into studs wherever you can. Scribe the frame to uneven brick and floors, then caulk the gaps before you paint.

A box-beam mantel is lighter and cheaper than a solid beam. Miter the boards at the corners so the grain runs continuously, then join the top and bottom with pocket screws. A floating shelf on a cleat or steel rods also works, provided it meets the clearance rules.

Finish the surround

Seal MDF faces and cut edges with a shellac-based or oil primer before painting. MDF takes paint unevenly if it isn’t sealed.

Some DIYers build a lightweight frame and skim it with a plaster or joint-compound finish to look like stone. Whether that’s allowed near a fire depends on the frame underneath, and on the clearance rules for that frame, not on the finish alone.

Wall panels: noncombustible vs. combustible

Wall panels come in two groups.

  • Noncombustible: Porcelain slab, sintered stone, fiber cement, steel and microcement. These can go in the clearance zone when installed as listed.
  • Combustible: Wood slats, MDF board-and-batten, and PVC or polyurethane 3D panels. Keep them outside the clearance zone.

Faux stone and faux brick panels are often lightweight plastic or foam, so treat them as combustible unless the listing says otherwise. Fire-rated acoustic slat panels still burn. A fire-rated coating, such as an ASTM E84 Class A rating, means the surface spreads flame slowly. It doesn’t mean the panel is noncombustible.

For a stone look that’s noncombustible, see stone fireplace surrounds. For shiplap near the fire, see shiplap fireplace install and finish steps.

Gas and electric surrounds

Gas units have their own rules, so read the manual before you frame or cover anything. Never cover prefab louvers, vents or gas control access panels. Turn off the gas and let the unit cool before you work around it.

An electric unit needs no venting, so it’s easier to frame around. The unit’s own clearances still apply, and its heater outlet usually needs clear space in front.

Whether a gas insert fits an existing firebox depends on the insert’s listing. Check with the manufacturer, and use a licensed installer for any gas work.

For the broader question of building a fireplace yourself, see can you make your own fireplace?.

Common mistakes

  • Treating fire-retardant paint as a substitute for a noncombustible facing
  • Assuming a gas fireplace has no clearance limits
  • Using one set of clearances for every fireplace
  • Calling a fire-rated acoustic panel noncombustible
  • Covering louvers or gas access panels to make the surround look cleaner