Quick answer
Measure the firebox in inches at more than one point, and write down every reading. For each dimension, use the smallest number, because that’s the one that controls fit. Then compare your numbers with the insert manufacturer’s minimum opening table. Don’t choose a unit by its size alone.
Before you measure
- Let the firebox cool completely, and clear out any ash and soot first.
- Use a rigid tape measure, a flashlight and a dust mask.
- Take photos of the fireplace, the room, the chimney and any model label inside the firebox.
- Get the insert’s manual or spec sheet. It tells you which numbers matter for that model.
Firebox measurements: width, height and depth
Record each measurement to the nearest quarter or eighth of an inch.
- Front width. Measure across the opening, from inside edge to inside edge, at the front face.
- Rear width. Measure across the back wall. Many masonry fireboxes taper toward the back, so this is often narrower than the front. Some manuals also ask for a width partway into the firebox, where the back of the unit will sit.
- Height. Measure from the hearth floor up to the underside of the lintel, the bar or beam across the top of the opening.
- Depth at the floor. Measure from the front face of the opening to the back wall at floor level.
- Depth at the top. Measure from the lintel back to the back wall at the top of the insert’s height. Back walls often slope forward, so this can be shallower than the depth at the floor.
Damper and throat
Look up at the damper. A narrow damper, or a damper frame that sticks out, can block an insert from sliding in or a liner from passing through. Measure the damper opening and the throat above it. Installers often remove the damper frame, so ask your installer what they plan to do.
Hearth, mantel and face
- Hearth. Measure the depth of the noncombustible hearth in front of the opening. Most inserts need a hearth extension of a set depth. The manual gives the figure, which is often around 16 to 18 inches but varies by model.
- Mantel and trim. Measure the distance from the top of the opening up to the mantel, and note the width and projection of any mantel legs or side trim. Clearances are set by the model, so compare these with the manual.
- Face. Measure the flat area around the opening, so you can choose a surround panel. Surrounds come in standard sizes and only cover gaps within their size range. Oversize options exist.
Chimney and flue
The liner is sized from the chimney, so note these points:
- Flue size. Measure the inside of the flue tile, not the outside or the size you were told. Old clay flues often measure smaller inside than their labeled size.
- Chimney height. Measure from the top of the insert to the top of the chimney. Your installer adds allowances for fittings, so ask for the exact figure.
- Bends. Note any bends in the flue. A bend needs extra liner length.
If you’re unsure whether the chimney needs a new liner, see whether you need a chimney liner for a fireplace insert.
Masonry or factory-built?
The type of firebox changes what you can install.
- A masonry fireplace takes most inserts, as long as the opening and chimney fit the unit.
- A factory-built (prefab) firebox needs an insert that’s listed for that particular firebox, and the manufacturer has to approve the combination. On a prefab unit, measure the inner working opening, not the decorative stone or louvers around it.
If you’re not sure which type you have, insert vs zero-clearance fireplace explains how to check.
Compare your numbers with the manual
Check each measurement against the manual’s minimum fireplace opening table. Leave a little extra room for the liner and for adjusting the unit. A fit that is just barely possible can make installation difficult. Once the numbers work, it’s worth asking whether the unit’s heat output suits the room. Are fireplace inserts worth it? covers that question. For the range of styles and types, see fireplace inserts: types and models.
Use this checklist before you order:
- Front width
- Rear width
- Height under the lintel
- Depth at the floor
- Depth at the top
- Damper opening and throat
- Hearth depth
- Mantel and trim clearances
- Face size for the surround
- Flue inside dimensions and chimney height
Common mistakes
- Measuring only the front width and height. The depth at the top and the rear width often decide whether the unit fits.
- Assuming the surround covers any gap. It only covers gaps within its size range.
- Ignoring the mantel clearance. The required clearance is set by each model.
- Ignoring the damper. Damper frames often block installation.
Safety
Measure a cold, swept fireplace. Wear a dust mask around soot, and don’t reach into the firebox while it still holds heat.